Fume hoods: what to plan before you buy

Published 6 min read

A fume cupboard protects the people in the lab from vapours, dust and aerosols. It only works if the right type is chosen, sited well and connected to services that can support it.

This guide covers the main types, how they are tested, and the questions to settle before you order.

Laboratory bench with pipettes and sample tubes

How a ducted hood works

How a ducted fume hood works
1234
  1. 1Room air is drawn in through the sash opening
  2. 2The baffle spreads the airflow evenly across the work area
  3. 3Vapours are carried up into the exhaust duct
  4. 4The duct exhausts outside the building

The main types

The main types
TypeHow it worksSuits
DuctedDraws air in at the front and exhausts it outside the buildingMost hazardous chemistry, especially volatile or high-volume work
Recirculating (ductless)Filters the air and returns it to the roomWhere ductwork is impractical and the filter suits the specific contaminants
Variable air volume (VAV)Reduces extract as the sash closes to save energyLabs with many hoods and a controlled supply system
High-heat and acid-dutyBuilt for heat and aggressive acid loadsPerchloric acid and similar work, usually ducted with wash-down surfaces

Typical values for guidance. Final specification is confirmed per project.

How hoods are tested

Ducted fume cupboards are tested under the EN 14175 series. Part 3 covers type testing of safety and performance, including face velocity and containment. Part 4 covers on-site testing, with commissioning checks on face velocity, extract volume flow, containment and alarms. VAV hoods add Part 6, high-heat and acid hoods Part 7, and recirculating filtration hoods are tested separately under EN 17242.

Face velocity, the speed of air through the opening, is a key figure. A typical value quoted for hazardous work is around 0.5 m/s, but the requirement comes from the standard and your local rules, so confirm it with your safety officer.

Plan these before you order

  • Exhaust and make-up air

    A ducted hood needs building exhaust capacity and replacement air. Agree this with the services contractor early.

  • Siting

    Away from doors, busy walkways and supply diffusers that disturb airflow at the opening.

  • Chemicals used

    The work decides the type, the worktop and the liner. Strong acids and high heat need special-duty construction.

  • Services and finish

    Taps, gas and power drops, a compatible worktop and the finishes around the hood.

  • Commissioning

    Plan the on-site tests and who signs them off before handover.

Frequently asked questions

Ducted or recirculating?

Ducted is the usual choice for hazardous chemistry. Recirculating suits specific, filter-compatible uses where ducting is impractical. Match the choice to the chemicals and get supplier confirmation.

Do you supply the extraction fan and ducting?

Ducting and fans are normally part of the building services scope. We coordinate the interface and install the hood, service drops and surrounding finishes.

How often are hoods tested?

On commissioning and then routinely, as set by your safety rules and the standard. Keep the test records with the lab’s documentation.